DSpace@İnönü

Klima Santralleri için Tasarlan bir V-Profil Delikli Difüzörlü Boş Hücredeki Hava Akışının Sayısal Olarak İncelenmesi

Basit öğe kaydını göster

dc.contributor.author Şahin, Hüseyin Emre
dc.contributor.author Kamer, Muhammed Safa
dc.contributor.author Taçgün, Ekrem
dc.contributor.author Erdoğan, Ahmet
dc.contributor.author Sönmez, Kerim
dc.contributor.author Kaya, Ahmet
dc.contributor.author Aksoy, İ. Gökhan
dc.contributor.author Canbazoğlu, Suat
dc.date.accessioned 2020-10-20T19:02:48Z
dc.date.available 2020-10-20T19:02:48Z
dc.date.issued 2015
dc.identifier.citation ŞAHİN H. E,KAMER M. S,TAÇGÜN E,ERDOĞAN A,SÖNMEZ K,KAYA A,AKSOY İ. G,CANBAZOĞLU S (2015). Klima Santralleri için Tasarlan bir V-Profil Delikli Difüzörlü Boş Hücredeki Hava Akışının Sayısal Olarak İncelenmesi. Makine Teknolojileri Elektronik Dergisi (elektronik), 12(4), 71 - 83. en_US
dc.identifier.uri https://app.trdizin.gov.tr/makale/TVRreU1UVXpNdz09
dc.identifier.uri http://hdl.handle.net/11616/18448
dc.description.abstract Öz:Klima santrallerinde kullanılan fanların çıkış ağızlarının kesit alanı, fandan sonra gelen ısıtma/soğutma bataryaları, susturucu, filtre, karışım odası veya ısı geri kazanım vb. hücrelerin kesit alanından küçüktür. Klima santralinin verimli bir şekilde çalışabilmesi için, fanın üflediği havanın bir sonraki hücreye mümkün olan en düşük basınç düşüşü ve homojen hız dağılımı ile yayılması gerekir. Küçük bir kesit alanından çıkan havayı daha büyük bir kesit alanına yaymak için delikli difüzörlü boş hücreler kullanılmaktadır. Bu çalışmada, V-profilli delikli difüzörlü boş hücre kullanılmıştır. Bu durumda havanın boş hücreden sonraki üniteye yayılma durumu ve delikli difüzörlü boş hücrenin sebep olduğu basınç düşüşü farklı tepe açıları, delik geometrisi ve gözeneklilik için sayısal olarak araştırılmıştır. en_US
dc.description.abstract Abstract:Cross-sectional area of air existing of fans used in air handling units is smaller than cross-sectional area of chambers which are located next to the fan such as heating/cooling coils, silencer (muffler), filter or heat recovery elements. To make the air handling unit work efficiently, it is required that the air is blown through fan diffuses with as low as possible pressure loss and homogen velocity distribution. Emptychambers with perforated V-profile diffuser is used to diffuse from small cross-sectional area to large cross sectional area. In this study, an empty chamber with perforated diffuser whose geometry is square based truncated pyramid is used. In this case, it is numerically investigated that both diffusion of air to the next unit and pressure loss caused by empty chamber with perforated V-profile diffuser for different peakangle, hole geometry and porosity. en_US
dc.language.iso tur en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Klima Santralleri için Tasarlan bir V-Profil Delikli Difüzörlü Boş Hücredeki Hava Akışının Sayısal Olarak İncelenmesi en_US
dc.title.alternative A Numerical Investigation of Air Flow in an Empty Chamber With Perforated V-Profile Diffuser Designed For Air Handling Units en_US
dc.type article en_US
dc.contributor.department İnönü Üniversitesi en_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster