DSpace@İnönü

Aort Kapak Alanı Hesaplanmasında Transözefajial Ekokardiyografi İle Transtorasik Ekokardiyografinin Karşılaştırılması

Basit öğe kaydını göster

dc.contributor.author Özdemir, Ramazan
dc.contributor.author Tuncer, Cemal
dc.contributor.author Güven, Aytekin
dc.contributor.author Pekdemir, Haşan
dc.contributor.author Sezgin, Alpay Turan
dc.contributor.author Müderrrisoğlu, Haldun
dc.date.accessioned 2015-08-31T12:27:58Z
dc.date.available 2015-08-31T12:27:58Z
dc.date.issued 1998
dc.identifier.citation Özdemir, R.,Tuncer, C.,Güven, A., Pekdemir, H.,Sezgin, Alpay T.,Müderrrisoğlu, H.,(1998). Aort Kapak Alanı Hesaplanmasında Transözefajial Ekokardiyografi İle Transtorasik Ekokardiyografinin Karşılaştırılması,Turgut Özal Tıp Merkezi Dergisi, 5 (4). 272-274. tr_TR
dc.identifier.uri http://www.totmdergisi.org/articles/1998/volume5/issue4/1998_5_4_14.pdf
dc.identifier.uri http://hdl.handle.net/11616/2579
dc.description Turgut Özal Tıp Merkezi Dergisi, 5 (4). 272-274. tr_TR
dc.description.abstract Kalp kapaklarının değerlendirilmesinde transözefajial ekokardiyografinin (TEE) transtorasik ekokardiyografiye (TTE) üstünlüğü bilinmektedir. Bu çalışmada aort kapak alanı hesaplanmasında duyarlılık açısından TEE ile TTE arasında fark olup olmadığı tespit edilmek istendi. Çalışmaya TTE He kals/fik aort darlığı saptanan 3 kadın (yaş ort: 55+8 yıl), 12 erkek (yaş ort:58±7 yıl) olmak üzere toplam 15 hasta alındı. Hastaların aort kapak alanları TTE ile hesaplandı. Daha sonra premedikasyonun ardından TEE ile sol ventrikül çıkış traktüsü ölçüldü. Ardından süreklilik denklemi kullanılarak aort kapak alanı tekrardan değerlendirildi. TTE'de ortalama gradient 32 mmHg ölçüldü. TTE ile sol ventrikül çıkış traktüsü (LVOT) 1.8 cm ölçülürken, TEE'de 2.2 cm olarak değerlendirildi (p<0.05). Ölçülen LVOT değerlerine göre hesaplanan aort kapak alanı TTE'de 1 crri bulunurken TEE'de 1.4 cm2 olarak bulundu (p<0.01). TEE ile LVOT ölçümü gerçek değere daha yakm olarak tespit edilebildiğinden dolayı aort kapak alanının noninvaziv değerlendirilmesinde daha doğru bir yaklaşım olacağı kanısındayız. tr_TR
dc.description.abstract It is well known that; examination of heart valves by transesophageal echocardiography (TEE) is superior to transthorasic echocardiography (TTE). In this study we aimed to evaluate differences between TEE and TTE for measurement of aortic valve area. 3 women (mean age: 55+8) and 12 men (mean age: 58+7) total 15 patients with calcific aort stenosis were included in the study. Aortic valve area measured by TTE. After premedication, left ventricular outflow tractus (L VOT) was measured by TEE using continuity equation aort valve area measured again.Mean gradient was calculated 32 mmHg by TTE. L VOT was measured 1.8 cm by TTE while 2.2 cm by TEE (p<0.05). Referency to the LVOTmeasurments aort valve area was measured 1 err? by TTE and 1.4 err? by TEE. Because of examination of L VOT is more accurate by TEE, we belive that as a noninvasive method using TEE is more reliable for measurement of aortic valve area. tr_TR
dc.description.sponsorship - tr_TR
dc.language.iso tur tr_TR
dc.publisher Turgut Özal Tıp Merkezi Dergisi tr_TR
dc.rights Attribution 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by/3.0/us/ *
dc.subject Transözefajial ekokardiyografi tr_TR
dc.subject transtorasik ekokardiyograf tr_TR
dc.subject aort kapak alanı tr_TR
dc.title Aort Kapak Alanı Hesaplanmasında Transözefajial Ekokardiyografi İle Transtorasik Ekokardiyografinin Karşılaştırılması tr_TR
dc.title.alternative Comparing with transthorasic echocardiography and transesopheagia! echocardiography methods for measurement of aort vaive area tr_TR
dc.type Article tr_TR


Bu öğenin dosyaları:

Aşağıdaki lisans dosyası bu öğe ile ilişkilidir:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster

Attribution 3.0 United States Aksi belirtilmediği sürece bu öğenin lisansı: Attribution 3.0 United States