DSpace@İnönü

Kit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisi

Basit öğe kaydını göster

dc.contributor.author Temel, İsmail
dc.contributor.author Çığlı, Ahmet
dc.contributor.author Türköz, Yusuf
dc.contributor.author Özerol, Elif
dc.contributor.author Gözükara, Engin M.
dc.date.accessioned 2015-11-02T10:15:58Z
dc.date.available 2015-11-02T10:15:58Z
dc.date.issued 1997
dc.identifier.citation Temel, İ.,Çığlı, A.,Türköz, Y.,Özerol, E.,Gözükara, Engin M.,(1997). Kit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisi.Turgut Özal Tıp Merkezi Dergisi, 4 (2).182-184 ss. tr_TR
dc.identifier.uri http://www.totmdergisi.org/articles/1997/volume4/issue2/1997_4_2_11.pdf
dc.identifier.uri http://hdl.handle.net/11616/2647
dc.description [Journal of Turgut Ozal Medical Center 1997;4(2):182-186] tr_TR
dc.description.abstract Beckman Synchron CX3 otoanalizörü kit bağımlı bir klinik analizördür. Kolay kullanımı, doğru ve kesin sonuçları ile 24 saat sürekli çalışma gibi avantajlarından dolayı laboratuvarımızda acil analizlerde kullanılmaktadır. Fakat cihazın kapalı sistem olması, çok fazla bakım ve aşırı miktarda reaktife ihtiyaç duyması gibi bazı önemli dezavantajları da vardır. Özellikle reaktif fiyatının yüksek olması nedeniyle alternatif reaktif aramak zorunda kaldık ve Synchron CX3 de kullandığımız bazı reaktifleri ürettik. Orijinal ve ürettiğimiz reaktiflerin lineeritesini kıyasladığımızda her ikisinin de aynı kullanılabilir lineer test aralıklarına sahip olduklarını gördük (serum: 0 ile 25 mg/dL ; idrar: 10 ile 40 mg/dL). Kontrol serumu kullanarak, sonuçların doğruluğunu araştırdık ve aralarındaki korelasyon katsayısının 0.999 a eşit olduğunu bulduk. Ayrıca farklı serum ve idrar örneklerinden elde edilen sonuçları lineer regresyon ile kıyasladık ve aralarındaki ilişkinin y = 0.98lx - 0.02 olduğunu saptadık Bunlara ilaveten her iki çözeltinin de hemolizden etkilenmediğini fakat yüksek miktarlarda lipemi ve bilirübin varlığından etkilendiklerini tespit ettik. Sonuç olarak laboratuvarımızda ürettiğimiz kreatinin reaktifı ile orijinal Beckman reaktifinin tamamen aynı özellikleri taşıdığını gördük, ancak ürettiğimiz reaktif orijinal reaktiften en az 10 kat daha ucuzdu. tr_TR
dc.description.abstract The Beckman Synchron CX3 otoanalyzer is a reagent-dependent clinical analyzer. Because of its advantages such as easy usage, accurate and precise results and working continuously for 24 hours it is used in our laboratory for stat analysis. But the analyzer has also some important disadvantages. It has an unopened system, requires much more maintenance procedures and large reagent volum. Because of its too high reagent cost we were obligated to search an alternative reagent and have produced some reagents used on the Synchron CX3. When we compared linearity of the reagents, we observed that they had same usable lineer test ranges (serum: from 0 to 25 mg/dL ; urine: from 10 to 40 mg/dL). We searched accuracy of the results using same control serum and found correlation coefficient among them equals to 0.999. We also compared the results obtained from different serum and urine samples by linear regression, and found the relation between them as y = 0.981x - 0.02. In addition to these criteria, we determined that both of reagents were not affected from hemolysis but were affected from high degress of lipemia and bilirubinemia. ^s a result, we observed that creatinine reagent produced in our laboratory had completely same properties with original Beckman creatinine reagent, but our reagent was cheaper than original reagent at least 10 times. tr_TR
dc.language.iso tur tr_TR
dc.publisher İnönü Üniversitesi Tıp Fakültesi Dergisi tr_TR
dc.rights info:eu-repo/semantics/openAccess tr_TR
dc.subject Synchron CX3 tr_TR
dc.subject Kreatinin çözeltisi tr_TR
dc.title Kit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisi tr_TR
dc.title.alternative An alternative creatinine reagent for the reagent-dependent Beckman Synchron CX3 analyzer tr_TR
dc.type article tr_TR
dc.relation.journal Turgut Özal Tıp Merkezi Dergisi tr_TR
dc.contributor.department İnönü Üniversitesi tr_TR
dc.contributor.authorID TR6818 tr_TR
dc.contributor.authorID TR107816 tr_TR
dc.contributor.authorID TR7064 tr_TR
dc.contributor.authorID TR5774 tr_TR
dc.identifier.volume 4 tr_TR
dc.identifier.issue 2 tr_TR
dc.identifier.startpage 182 tr_TR
dc.identifier.endpage 186 tr_TR