dc.contributor.author |
Harorlı, Osman Tolga |
|
dc.contributor.author |
Barutcigil, Çağatay |
|
dc.contributor.author |
Kürklü, Duygu |
|
dc.contributor.author |
Gündoğdu, Mustafa |
|
dc.contributor.author |
Duymuş, Zeynep Yeşil |
|
dc.date.accessioned |
2016-10-24T07:30:52Z |
|
dc.date.available |
2016-10-24T07:30:52Z |
|
dc.date.issued |
2013 |
|
dc.identifier.citation |
Harorlı, O. Tolga,Barutcigil, Ç. Kürklü, D. Gündoğdu, M. Duymuş, Z. Yeşi, (2013).Farklı yüzey örtücü uygulamalarının kompozit rezinin yüzey pürüzlülüğüne etkisi.İnönü Üniversitesi Sağlık Bilimleri Dergisi 2013; 2: 23-26 ss. |
tr_TR |
dc.identifier.uri |
https://www.inonu.edu.tr/uploads/old/3/260/23-26makale.pdf |
|
dc.identifier.uri |
http://hdl.handle.net/11616/4846 |
|
dc.description |
İnönü Üniversitesi Sağlık Bilimleri Dergisi 2013; 2: 23-26 |
tr_TR |
dc.description.abstract |
Bu çalışmanın amacı farklı yüzey örtücü uygulamalarının bir nanofil hibrit kompozit rezinin yüzey pürüzlülüğüne olan etkisini
araştırmaktır. Nanofil kompozit reçine kullanılarak otuz beş disk şeklinde numune hazırlandı ve yüzeyleri alüminyum oksit diskler ile
düzeltildi. Yüzey örtücü uygulamaları öncesi ve sonrası, ortalama yüzey pürüzlülük değerleri (Ra) bir profilometre ile ölçüldü ve sonuçlar
istatistiksel olarak tek yönlü ANOVA ve Tukey testi ile değerlendirildi. Test edilen uygulamaların hiçbirinde yüzey pürüzlülüğü
azalmadı. Kontrol grubu ile Equia Coat ve tek aşamalı Single Bond uygulamaları arasında istatistiksel bir fark saptanmazken, iki
aşamalı Single Bond uygulaması ve Protect-it uygulaması yüzey pürüzlülüğünde artışa neden oldu. Test edilen yüzey örtücü
işlemlerinden hiç biri aliminyum oksit diskler ile bitirilmiş nanofill kompozit rezinin yüzey pürüzlülüğünü azaltamamıştır. |
tr_TR |
dc.description.abstract |
The aim of this study was to investigate the effect of different surface sealing applications on the surface roughness of a nanofill hybrid
composite resin.
Thirty five disc-shaped specimens were made by using a nanofill composite resin (3M Z550) and finished with aluminium oxide discs.
Before and after surface sealant applications, average surface roughness values (Ra) were measured with a profilometry and the results
were statistically evaluated by using two-way ANOVA and Tukey’s test. None of the tested applications improved the surface roughness.
There was not a statistical different between control and Equia Coat and one step Single Bond application however two step Single Bond
application and Protect it caused an increased surface roughness. Tested surface sealants did not improved the roughness of nanofill
composite resin finished with aluminum oxide discs. |
tr_TR |
dc.language.iso |
tur |
tr_TR |
dc.publisher |
İnönü Üniversitesi Sağlık Bilimleri Dergisi |
tr_TR |
dc.rights |
info:eu-repo/semantics/openAccess |
tr_TR |
dc.subject |
Dental |
tr_TR |
dc.subject |
Kompozit rezinler |
tr_TR |
dc.subject |
Yüzey Özellikler |
tr_TR |
dc.subject |
Dental |
tr_TR |
dc.subject |
Composite Resins |
tr_TR |
dc.subject |
Surface Properties |
tr_TR |
dc.title |
Farklı yüzey örtücü uygulamalarının kompozit rezinin yüzey pürüzlülüğüne etkisi |
tr_TR |
dc.title.alternative |
Effect of different surface sealing applications on surface roughness of a composite resin |
tr_TR |
dc.type |
article |
tr_TR |
dc.relation.ispartof |
İnönü Üniversitesi Sağlık Bilimleri Dergisi |
tr_TR |
dc.department |
Akdeniz Üniversitesi Diş Hekimliği Fakültesi |
tr_TR |
dc.authorid |
TR117635 |
tr_TR |
dc.authorid |
TR20491 |
tr_TR |
dc.authorid |
TR22640 |
tr_TR |
dc.identifier.volume |
2 |
tr_TR |
dc.identifier.issue |
2 |
tr_TR |
dc.identifier.startpage |
23 |
tr_TR |
dc.identifier.endpage |
26 |
tr_TR |