Does obesity have an impact on the radiation exposure during lumbosacral transforaminal epidural steroid injections? Retrospective study

Basit öğe kaydını göster

dc.contributor.author Sencan, Savas
dc.contributor.author Giray, Esra
dc.contributor.author Ulutatar, Firat
dc.contributor.author Gunduz, Osman Hakan
dc.date.accessioned 2022-03-08T09:40:53Z
dc.date.available 2022-03-08T09:40:53Z
dc.date.issued 2019
dc.identifier.citation Sencan, S., Giray, E., Ulutatar, F., & Hakan Gunduz, O. (2021). Does obesity have an impact on the radiation exposure during lumbosacral transforaminal epidural steroid injections? Retrospective study . Annals of Medical Research en_US
dc.identifier.uri http://hdl.handle.net/11616/54734
dc.description.abstract Aim: To find out whether obesity or injection level have an impact on the amount of radiation exposure during fluoroscopy-guided lumbosacral transforaminal epidural steroid injections (TFESIs).Material and Methods: Patients aged 19-65 years who underwent lumbosacral transforaminal epidural steroid injection were retrospectively reviewed. Eighty-three patients with a mean age of 42.7±13.2 (19-65) years with signs and symptoms of unilateral lumbar radicular pain due to single level disc herniation were included. Subjects were categorized as normal weighted (18.5≤body mass index (BMI) ≤ 24.9), overweighed (25≤BMI30) and obese (BMI≥30) according to World Health Organization BMI criteria. All patients were given unilateral TFESIs, including39 (47%) L5, and 44 (53%) S1 level. Radiation exposure dose and procedure time was automatically measured by fluoroscope.Results: Radiation dosage increased significantly with increasing BMI (p=0.0001). No statistically significant differences were found when three groups’ procedure durations and NRS scores were compared (>0.05). The radiation dosages and procedure durations between the two different injection levels (L5 and S1) were not found to be statistically significant (>0.05). Conclusion: Obesity is associated with increased radiation exposure independent of procedure duration and the injection level. en_US
dc.language.iso eng en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Does obesity have an impact on the radiation exposure during lumbosacral transforaminal epidural steroid injections? Retrospective study en_US
dc.type article en_US
dc.relation.journal Annals of Medical Research en_US
dc.contributor.department İnönü Üniversitesi en_US