DSpace@İnönü

Correlation of pulse oximetry oxygen saturation with blood gas arterial oxygen saturation in patients with heart failure reduced ejection fraction: Prospective cohort study

Basit öğe kaydını göster

dc.contributor.author Gok, Gulay
dc.contributor.author Cinar, Tufan
dc.contributor.author Nurkalem, Zekeriya
dc.contributor.author Duman, Dursun
dc.date.accessioned 2022-03-09T09:42:18Z
dc.date.available 2022-03-09T09:42:18Z
dc.date.issued 2020
dc.identifier.citation Gok, G., Cinar, T., Nurkalem, Z., & Duman, D. (2021). Correlation of pulse oximetry oxygen saturation with blood gas arterial oxygen saturation in patients with heart failure reduced ejection fraction: Prospective cohort study . Annals of Medical ResearcH en_US
dc.identifier.uri http://hdl.handle.net/11616/54930
dc.description.abstract Aim: An estimation of accurate oxygen saturation is a critical in the management of patients with heart failure (HF). However, obtaining peripheral arterial blood samples may be technically difficult in some cases. The purpose of this study was to evaluate the correlation of pulse oximetry SO2 with arterial SO2 in patients with HF reduced ejection fraction (HFrEF). Material and Methods: In total, 29 consecutive patients who were admitted to cardiology clinics with HFrEF were prospectively enrolled in this study. We enrolled all patients if the chief physician ordered an atrial blood gas analysis. Simultaneous atrial blood gas sample and pulse oximetry measurements were collected and compared. The strength of association between atrial blood gas and pulse oximetry measurements was determined by Pearson correlation and Bland and Altman analysis.Results: We evaluated 29 heart failure patients (the mean age was; 70.7±10.9, 44.8 % of patients were male) with a mean EF of 29.6 ± 5.5. We observed that the mean pulse oximetry SO2 and arterial SO2 in the study were 92.8 ± 4.4 and 93 ± 5.2, respectively. We found significantly positive linear correlation between two methods according to Pearson analysis (r = 0.683, p 0.001). A low bias was found between two methods according to Bland and Altman method (-0.2296, p = 0.23).Conclusion: The present data may suggest that pulse oximetry oxygen saturation is an acceptable substitute for the arterial oxygen saturation in patients with HFrEF. en_US
dc.language.iso eng en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Correlation of pulse oximetry oxygen saturation with blood gas arterial oxygen saturation in patients with heart failure reduced ejection fraction: Prospective cohort study en_US
dc.type article en_US
dc.relation.ispartof Annals of Medical Research en_US
dc.department İnönü Üniversitesi en_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster