Rapid Detection of Bloodstream Pathogens in Liver Transplantation

Basit öğe kaydını göster

dc.contributor.author Otlu, B
dc.contributor.author Bayindir, Y
dc.contributor.author Ozdemir, F
dc.contributor.author Ince, V
dc.contributor.author Cuglan, S
dc.contributor.author Hopoglu, M
dc.contributor.author Yakupogullari, Y
dc.contributor.author Kizilkaya, C
dc.contributor.author Kuzucu, C
dc.contributor.author Isik, B
dc.contributor.author Yilmaz, S
dc.date.accessioned 2022-03-30T13:21:48Z
dc.date.available 2022-03-30T13:21:48Z
dc.date.issued 2015
dc.identifier.uri http://hdl.handle.net/11616/59724
dc.description.abstract Background. Bloodstream infection (BSI) is an important concern in transplant patients. Early intervention with appropriate antimicrobial therapy is critical to better clinical outcome; however, there is significant delay when conventional identification methods are used.
dc.description.abstract Methods. We aimed to determine the diagnostic performance of the FilmArray Blood Culture Identification Panel, a recently approved multiplex polymerase chain reaction assay detecting 24 BSI pathogens and 3 resistance genes, in comparison with the performances of conventional identification methods in liver transplant (LT) patients. A total of 52 defined sepsis episodes (signal-positive by blood culture systems) from 45 LT patients were prospectively studied.
dc.description.abstract Results. The FilmArray successfully identified 37 of 39 (94.8%) bacterial and 3 of 3 (100%) yeast pathogens in a total of 42 samples with microbial growth, failing to detect only 2 of 39 (5.1%) bacterial pathogens that were not covered by the test panel. The FilmArray could also detect additional pathogens in 3 samples that had been reported as having monomicrobial growth, and it could detect Acinetobacter baumannii in 2 samples suspected of skin flora contamination. The remaining 8 blood cultures showing a positive signal but yielding no growth were also negative by this assay. Results of MecA, KPC, and VanA/B gene detection were in high accordance. The FilmArray produced results with significantly shorter turnaround times (1.33 versus 36.2, 23.6, and 19.5 h; P < .05) than standard identification methods, Vitek II, and Vitek MS, respectively.
dc.description.abstract Conclusions. This study showed that the FilmArray appeared as a reliable alternative diagnostic method with the potential to mitigate problems with protracted diagnosis of the BSI pathogens in LT patients.
dc.source TRANSPLANTATION PROCEEDINGS
dc.title Rapid Detection of Bloodstream Pathogens in Liver Transplantation
dc.title Patients With Film Array Multiplex Polymerase Chain Reaction Assays:
dc.title Comparison With Conventional Methods