DSpace@İnönü

Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty

Basit öğe kaydını göster

dc.contributor.author Kalcioglu, M. Tayyar
dc.contributor.author Uzun, Ismail Hakki
dc.contributor.author Yalcin, Muhammet
dc.contributor.author Malkoc, Meral Arslan
dc.contributor.author Öğreten, Ayse Tuba
dc.contributor.author Hanege, Fatih Mehmet
dc.date.accessioned 2020-06-01T11:39:12Z
dc.date.available 2020-06-01T11:39:12Z
dc.date.issued 2015-01
dc.identifier.citation Kalcioglu, M. T., Uzun, I.H., Yalcin, M., Malkoc, M.A., Ogreten, A.T., Hanege, F.M. Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty. (2015). BALKAN MEDICAL JOURNAL. tr_TR
dc.identifier.issn 2146-3123
dc.identifier.issn 2146-3131
dc.identifier.other DOI: 10.5152/balkanmedj.2015.15829
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/15616
dc.description BALKAN MEDICAL JOURNAL Volume: 32 Issue: 1 Pages: 23-29 tr_TR
dc.description.abstract Background: Glass ionomer cements (GIC) have been widely used in dentistry for many years. In recent years, GIC have also been used for ossiculoplasty. The bond strength of GIC used in ossiculoplasty and the way they may change over the years in the cementation area are being questioned. The bonding strength of the substance may be of importance for long-term outcomes. Aims: The aim of this study was to investigate the bond strength of different GIC on ossicles. Study Design: In vitro study. Methods: Twenty ossicles were obtained from patients who had undergone ear surgery. All specimens were randomly divided into four subgroups. All specimens were inserted into a specially designed apparatus for shear bond strength (SBS) testing. The tested materials [Aqua Meron (AM), Aqua Cem (AC), Ketac Cem (KC), and Otomimix CPB (OH)] were prepared and applied according to the manufacturer's instructions. The SBS was tested using a universal testing machine at a crosshead speed of 0.5 mm/min. Results: The mean SBSs were found to be 13.28 MPa, 23.43 MPa, 8.51MPa, and 1.78 MPa for AM, AC, KC, and OH, respectively. AC had the highest SBS, which was statistically significantly different from that of KC and OH (p<0.05). Both AM and KC had higher SBS than OH (p<0.05). Conclusion: The results obtained in this study by investigating the bone-bonding strength of cements widely used in ossiculoplasty demonstrate that some of these substances have a greater ability to bond to ossicles compared to others. Further clinical investigations are needed to test different parameters. tr_TR
dc.language.iso en tr_TR
dc.publisher AVES, tr_TR
dc.subject Bone cement tr_TR
dc.subject bond strength tr_TR
dc.subject ossiculoplasty tr_TR
dc.subject ossicles tr_TR
dc.title Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty tr_TR
dc.type Article tr_TR


Bu öğenin dosyaları:

Dosyalar Boyut Biçim Göster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster